Year : 2022  |  Volume : 11  |  Issue : 1  |  Page : 49

Stainless steel vs. titanium miniscrew implants: Evaluation of stability during retraction of maxillary and mandibular anterior teeth


1 Department of Dentistry, Government Institute of Medical Sciences, Greater Noida, India
2 Department of Orthodontics and Dentofacial Orthopedics, Santosh Dental College and Hospital, Ghaziabad, Uttar Pradesh, India
3 Grewal Dental Practice, Aster Avenue, Phase 4, DLF, Gurgaon, Haryana, India

Correspondence Address:
Sandeep Kumar Pandey
Department of Dentistry, Government Institute of Medical Sciences, Greater Noida, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jos.jos_198_21

Rights and Permissions

OBJECTIVES: This study was aimed to compare the stability of stainless steel and titanium miniscrew implants of the same diameter and length during en masse retraction of maxillary and mandibular anterior teeth. MATERIALS AND METHODS: Forty miniscrew implants (1.3 mm diameter and 8 mm length) were placed in 10 patients (20 titanium and 20 stainless steel). Stability was checked at insertion (T0), at one month (T1), and at sixth months (T2) and the amount of retraction was recorded in millimeters. RESULTS: Titanium and stainless steel implants were equally stable at the time of insertion. At T1, three titanium miniscrew implants showed grade 2 mobility, whereas seven stainless steel miniscrew implants showed grade 2 mobility. For T2, none of the titanium miniscrew implants had grade 2 mobility while four stainless steel miniscrew implants resulted in grade 2 mobility. Both had an equal frequency of grade 3 and grade 4 mobility. However, the difference in the stability was not statistically significant. No statistical significance was found when the amount of retraction achieved by titanium and stainless steel miniscrew implants was compared between the maxillary and mandibular arches. CONCLUSION: Both titanium and stainless steel miniscrew implants provide good anchorage and remain stable during en masse retraction of maxillary and mandibular anterior teeth. Thus, both miniscrews are clinically effective.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1708    
    Printed82    
    Emailed0    
    PDF Downloaded189    
    Comments [Add]    

Recommend this journal