Home Print this page Email this page Small font size Default font size Increase font size   Users Online: 1214
Home About us Editorial board Search Browse articles Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2023  |  Volume : 12  |  Issue : 1  |  Page : 20

Comparison of shear bond strength of bonded stainless steel brackets using three different light curing systems: An in vitro study


1 Senior Lecturer, Department of Orthodontics and Dentofacial Orthpaedics, Peoples Dental Academy, Bhopal Madhya Pradesh, India
2 Reader, Department of Orthodontics and Dentofacial Orthpaedics, Buddha Institute of Dental Sciences and Hospital, Patna, Bihar, India
3 Senior Lecturer, Department of Orthodontics and Dentofacial Orthpaedics, Hi Tech Dental College and Hospital, Bhubneshwar, Odisha, India
4 Professor and Head, Department of Orthodontics and Dentofacial Orthpaedics, Maharana Pratap College of Dentistry and Research Centre, Gwalior, Madhya Pradesh, India
5 Consultant Orthodontist, Mumbai, Maharastra, India
6 Senior Lecturer, Department of Orthodontics and Dentofacial Orthpaedics, Peoples College of Dental Sciences and Research Centre, Bhopal Madhya Pradesh, India

Correspondence Address:
Ashish Kushwah
FH- 484, Deen Dayal Nagar, Gwalior, Madhya Pradesh – 474 020
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jos.jos_83_22

Rights and Permissions

OBJECTIVES: To evaluate and compare the shear bond strength of stainless-steel brackets using three different light curing units MATERIAL AND METHODS: Using three LED curing units (3M ESPE Elipar, Ivoclar bluephase, and Woodpecker I LED light cure), 120 precoated metal brackets (Gemini series, 3M Unitek) were cured. The shear bond strength was recorded using a universal testing machine. RESULT: The shear strength of the bracket in different light-curing systems was examined with ANOVA test. The mean shear strength of group A, group B, and group C were 16.03 ± 14.30 MPA, 16.86 ± 11.89 MPA, and 20.51 ± 19.40, respectively. The result of the analysis shows that there is a major difference in shear bond strength of these three different light-curing systems with F value = 3.94 and P value 0.04 CONCLUSION: We used three LED light-curing units with different intensities and manufacturing companies. The result showed that woodpecker I LED light had significantly highest mean SBS than the other two (Elipar LED curing light and 3M ESPE, Ivoclar bluephase).


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed844    
    Printed116    
    Emailed0    
    PDF Downloaded90    
    Comments [Add]    

Recommend this journal