REVIEW ARTICLE |
|
Year : 2023 | Volume
: 12
| Issue : 1 | Page : 25 |
|
Methods of measuring distal canine movement and rotation- A review
Mohammed Nahidh, Yassir A Yassir
Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq
Date of Submission | 13-Sep-2022 |
Date of Decision | 12-Oct-2022 |
Date of Acceptance | 08-Dec-2022 |
Date of Web Publication | 28-Apr-2023 |
Correspondence Address: Mohammed Nahidh Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad Iraq
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/jos.jos_82_22
This article provides an overview of the various methods for measuring distal canine movement and rotation during retraction. Various databases, including PubMed Central, Science Direct, Wiley Online Library, the Cochrane Library, Textbooks, Google Scholar, and Research Gate, and a manual search up until September 2022, were used to search for various methods of measuring distal canine movement and rotation during retraction. After excluding the duplicate articles, the papers explaining these techniques were included. Four significant techniques were identified. The digital method with 3D superimposition is the safest, most accurate, and most accessible of the methods reviewed.
Keywords: Canine distal movement, digital scanner, rotation
How to cite this article: Nahidh M, Yassir YA. Methods of measuring distal canine movement and rotation- A review. J Orthodont Sci 2023;12:25 |
Introduction | |  |
Approximately 50% of orthodontic cases require dental extraction, with the maxillary first bicuspids being the most often extracted teeth.[1]
After extraction of the premolars, the canines are distalized to the extraction region employing a wide variety of mechanisms. These were frictional (sliding) or nonfrictional (nonsliding) mechanisms.[2],[3],[4]
Frictional mechanics may have disadvantages such as canine tilting, archwire binding that inhibits movement, anchorage loss, and incisor extrusion.[5] However, orthodontists frequently like this mechanism because it is accessible in the application, requires less chairside time, and provides superior control of the entire dental arch with a single archwire.[6]
This review was conducted to explain different methods used to measure the amount of distal canine movement and rotation using different approaches.
Methods | |  |
Methods of measuring distal canine movement and rotation were searched in different databases, including PubMed Central, Science Direct, Wiley Online Library, the Cochrane Library, Textbooks, Google Scholar, and Research Gate, and a manual search up until September 2022. The unrelvant and deplicated articles were excluded; finally 53 articles were included in this narrative review.
Methods of Measuring Distal Canine Movement | |  |
There are numerous techniques for measuring the velocity and magnitude of distal canine movement.
Clinically (Intraorally)
Using a sliding caliper, Huffman and Way[7] and Ziegler and Ingervall[8] determined the distance between the distal surface of the canine bracket and the vertical wire put into the flat acrylic plate covering the maxillary dental arch [Figure 1]. | Figure 1: Measuring the distal canine movement by sliding caliper intra-orally[8]
Click here to view |
Sonis[9] used a Boley gauge to calculate the distance between the mesial surface of the mesial wing of the second premolar bracket and the distal surface of the distal wing of the canine bracket. Hasan et al.[10] measured precisely using digital vernier calipers.
Mehta and Sable[11] used a bespoke acrylic occlusal split with integrated hooks corresponding to the distal edges of the lateral incisor brackets and a digital caliper to measure the distance between the hook and the center of the canine brackets.
Using a digital caliper, Pavlin et al.[12] measured the distance from the canine cusp tip to the miniscrew parallel to the occlusal plane [Figure 2]. | Figure 2: Measuring the distal canine movement (d) by digital caliper intra-orally[12]
Click here to view |
Khalid et al.[13] assessed the distance between the lateral incisor and canine on the maxillary arch at the mid-incisal, middle, and cervical thirds using vernier calipers.
Mezari and Ahmed[14] used a vernier caliper to measure the distance between the distal surface of the canine and the mesial surface of the second premolar on both sides prior to and after various intervals of canine retraction [Figure 3]a. | Figure 3: Different methods of measuring canine distal movement and rotation
Click here to view |
Using an electronic digital vernier, Sivarajan et al.[15] assessed the distance between the cusp tip of the canine and the mesiobuccal groove of the first molar [Figure 3]b.
Finally, using a digital caliper, Qamruddin et al.[16] measured the distance between the dental midline and the mesial surface of the canine [Figure 3]c. On the other hand, Shankar et al.[17] and Tawfik et al.[18] measured the rate of distal canine movement as the distance between the cusp tip of the canine and mesiobuccal cusp tip of the first molar.
Using study models
Lotzof et al.[19] used an acrylic palatal plug with wires extending toward the canine cusp points. They selected the central fossa of the first maxillary molar as the reference point, whereas Limpanichkul et al.[20] used the mesial contact point.
Dixon et al.[21] and Nightingale and Jones[22] determined the maximum distance between the cusp point of the canine and the buccal groove of the first permanent molar [Figure 3]b.
Sukurica et al.[23] assessed the perpendicular distance between the canine cusp tips and a reference line tangent to the interdental contact points of the maxillary central incisors and intersecting the mid-palatal raphe vertically.
Ravi et al.[24] drew a perpendicular line from the canine cusp tip to the median palatal raphe and then measured the difference between before and after retraction [Figure 3]d.
Similar to Mezari and Ahmed, Mezomo et al.[25] evaluated the distance between the contact points on the distal surface of the canines and the mesial surface of the second premolars.[14]
Using either photographed or scanned dental models, Aboul-Elaet al.,[26] Kalra et al.,[27] Hassan et al.,[28] and Alfawal et al.[29] calculated the distance between the median point of the third palatal rugae and the perpendicular line from the canine's cusp tip to the mid-palatal raphe [Figure 3]e.
Using a vernier caliper, Bhat et al.[30] measured the distance between the canine cusp tip and the second premolar fossa.
The distance between the distal edge of the canine bracket base and the mesial margin of the first molar band tube was determined by Abdul-Wahab et al.[31]
Finally, Alqadasi et al.[32] projected the buccal cusp tips of the second premolars and canines on the midpalatal raphe and measured the distance between the canine cusp tip and the line [Figure 3]f.
Radiographically
Thiruvenkatachari et al.[33] assessed the rate of canine retraction using lateral cephalometric radiographs as a reference to a stable cranial landmark. The maxilla used the vertical pterygoid plane, whereas the mandible employed the sella vertical plane.
Martins et al.[34] used a series of normal 45° oblique cephalograms obtained from both sides and superimposed them to determine the rate of canine distal movement.
Oz et al.[35] put L-shaped, 0.021 × 0.025 inch stainless steel reference wires into the canine brackets and molar tubes and evaluated the horizontal distance between these reference wires on both sides using a lateral cephalometric radiograph.
Monini et al.[36],[37] employed a vertical reference line perpendicular to the occlusal plane on both sides of oblique lateral cephalometric radiographs. The canine movement was indicated by the horizontal distance between the vertical reference line and the canine cusp point.
Finally, Abu-Shahba and Alassiry[38] used CBCT to determine the horizontal distance between the canine's tip and apex and a built line linking the points of maximal concavity of the posterior border of the palatine bone.
3D Assessment
El-Timamy et al.[39] scanned the research models and evaluated the canine movement over a period of four months using the superimposition technique and 3-shape analyzer software. The rate of distal canine movement was computed based on the change in canine position between successive models by measuring the perpendicular distance between the cusp tip of the canine and the median palatal raphe.
Ali and Chawshli,[40] using a CEREC Omnicam scanner and Laboratory CAM 15.0 software, evaluated the distance between the distal connecter of the canine and the mesial connecter of the second premolar on both sides before and after canine retraction [Figure 3]a.
Barsoum et al.[41] scanned the plaster models using an R500 3-shape laser scanner to turn them into digital models. The preretraction models were oriented and superimposed on the third rugae's medial points with the aid of three planes (sagittal, horizontal, and frontal). Using 3-shape Analyzer software, the total canine retraction was assessed as the perpendicular distance from the cusp tip of the canine to the frontal plane before and after six months of retraction.
Akın and Camcı[42] determined the monthly amount of canine retraction by superimposing digital models using the distal point of the canines as a reference point for subsequent assessments. The region between the lateral tips of the first and third rugae is used as a reference area for superimpositions [Figure 4]. | Figure 4: Measuring canine distal movement by local best-fit superimposition on the digital model[42] (a) Local best area, (b) Superimposed digital models
Click here to view |
El Gazzar et al.[43] scanned the stone models with a 3-shape scanner and superimposed the models with 3-shape analyzer software based on three locations on the third rugae. After locating the cusp tip in each digital model, the distance between the frontal plane and the canine cusp tip was measured and the amount of canine distal movement per month was determined based on the difference in position between subsequent models.
Albelasy and Abdelnaby[44] assessed the amount of canine distal movement after five months of retraction at the level of cusp tip by superimposing digital models using the software Ortho Analyzer.
Türedi and Yazıcıoğlu[45] determined the rate of canine distal movement at the level of the cusp tip of the maxillary canine and the tip of the mesiobuccal cusp of the maxillary second molar by superimposing digital models using the medial and lateral points of the third palatal rugae and the medial point of the first palatal rugae as references for superimposition.
Angel et al.[46] used the inferior tip of the incisive papilla and the medial end of the first rugae bilaterally close to the median raphe as reference points to superimpose the digital models and measured the rate of canine retraction at the cusp tip level at various time intervals using a 3D ruler of Dolphin 3D software.
Methods of Assessing Canine Rotation during Retraction | |  |
Ziegler and Ingervall[8] measured the angle produced between the medial palatal suture and a line passing between the mesial and distal contact points of the canines to assess the rotation of canines during retraction [Figure 3]g.
Agha and Al–Saleem[47] developed a new method for assessing canine rotation using a vernier with 0.1 mm accuracy to measure the linear distances (directly on the study model) from the mesial and distal contact points of the canine to the mid-palatal raphe before and after retraction, with the net result representing the amount of rotation.
The third approach combined the second and the method of Ziegler and Ingervall.[8] Here, the second method's measurements were converted to paper with the addition of the indicated angle[8] and discrepancies between pretreatment and post-treatment were measured. A protractor measured the angle with an accuracy of 0.5 mm degrees.
Discussion | |  |
This article outlined several techniques for measuring the distal canine's movement and rotation. Each has both benefits and drawbacks. The clinical or intra-oral approach may be imprecise if the access to the area of measurement affects the angle of holding the vernier or if it does not rely on fixed and dependable locations in some instances.
The same drawback of relying on unreliable reference points is also present in the study model approach and the method's dimensional change of the acrylic plug relies on this weakness. Changes in the dimensions of the impression materials and some tearing following removal are a further concern.
The radiographic method may have ethical and safety problems with the exposure to radiation and superimposition of teeth, particularly with lateral cephalometric X-ray, whereas the study model is safe, simple, and accurate.[25] The clinical procedures are less precise and error-prone than the models used in research.[15]
The superimposition of digital dental models is one of the most innovative instruments for calculating individual dental changes between two time points.[48] 3D assessment by the superimposition of the digital models from intra-oral scanner or scanned stone models is considered the superior method because the method of superimposition and digital measurements decreased the possibility of errors that could have occurred with other methods, in addition to the patient's comfort.[49] However, the technology for superimposing digital models has not been as thoroughly standardized as other common orthodontic procedures.[50]
Superimposition must be performed on stable reference points. The rugae area in the maxillary arch is the most correct portion for superimposition, notably the medial portion, as the lateral portion of the rugae may be impacted by headgear treatment,[51] extraction of the maxillary premolar,[52] and significant maxillary expansion.[53]
As per the majority of research, the growth changes in the vertical and sagittal planes surrounding the third rugae region are practically minimal.[54]
Thiruvenkatachari et al.[55] used stable spots on the palatal rugae and a stable region in the center of the hard palate in an effort to compare the accuracy of the 3D scanner to the measurements acquired from cephalometric radiography. They juxtaposed scans of models before and after therapy.
Cha et al.,[56] who evaluated the tooth movement measured by the superimposition of 3D images on the palatal rugae using the best-fit method on three implants that were considered stationary landmarks, determined that the medial point of the third rugae was the most stable point, confirming the findings of Frans van der Linden,[57] as it is the furthest away from the retracted anterior teeth. Jang et al.[58] concluded that the abovementioned landmarks might be relied upon as stable measuring points for tooth movement based on the stability of the posterior region of the palatal vault.
The same conclusion was obtained from a recent study performed by Garib et al.,[59] who used nine palatal landmarks [Figure 5], namely, the posterior limit of the incisive papilla, the medial edges of the second rugae, the medial and lateral edges of the third rugae, and two landmarks 10 mm distal to the medial edge of the third rugae landmarks to superimpose the maxillary arch at different intervals. In addition, they leveraged these landmarks to create an area of interest. The authors hypothesized that registration based on landmarks might be the preferred method for evaluating patients undergoing fixed orthodontic therapy. Furthermore, neither the enlargement of arches nor the closure of extraction gaps affected the location of these landmarks. | Figure 5: (a) Nine landmarks that used for registration on the palatal rugae. (b) Region of interest around the nine landmarks used for registration[59]
Click here to view |
Assuming that superimposition is performed on the most stable palatal landmarks, additional research is required to compare alternative methods for assessing distal canine movement as there is no study that compares the accuracy of different digital scanners and softwares in evaluating the amount of distal canine movement and rotation. On the other hand, no study used the digital photographs in evaluating the same prupose, so further studies are needed to verify these two methods. Merging Digital imaging and communication in medicine and stereolithography might be a promising method for measuring distal canine movement just like the direct method.
Conclusions | |  |
Direct measuring inside the patient's mouth is the simplest method; however, it lacks accuracy. Changes in dimensions and tearing of the impression materials may influence the dental model analysis measurements. Exposure to X-rays is deemed dangerous and is not recommended from an ethical standpoint. It is the preferred way to use an intra-oral scanner and digital superimposition on stable palatal landmarks because it is safe, simple, rapid, accurate, and does not disturb the patients.
Financial support and sponsorship
Nil.
Conflicts of interest
There are no conflicts of interest.
References | |  |
1. | de Sousa Dardengo C, Fernandes LQP, Júnior JC. Frequency of orthodontic extraction. Dental Press J Orthod 2016;21:54-9. |
2. | Kulshrestha R, Tandon R, Chandra P. Canine retraction: A systematic review of different methods used. J Orthod Sci 2015;4:1-8. |
3. | Nahidh M, Yassir AY, McIntyr GT. Different methods of canine retraction- Part 1. J Baghdad Coll Dentistry 2022;34:58-74. |
4. | Nahidh M, Yassir AY, McIntyr GT. Different methods of canine retraction- Part 2. J Baghdad Coll Dentistry 2023;35:58-75. |
5. | Gjessing P. Biomechanical design and clinical evaluation of a new canine retraction spring. Am J Orthod 1985;87:353-62. |
6. | Sandler J. Systematized orthodontic treatment mechanics. J Orthod 2002;29:153. |
7. | Huffman DJ, Way DC. A clinical evaluation of tooth movement along arch wires of two different sizes, Am J Orthod 1983;83:453-9. |
8. | Ziegler P, Ingervall B. A clinical study of maxillary canine retraction with a retraction spring and with sliding mechanics. Am J Orthod Dentofacial Orthop 1989;95:99-106. |
9. | Sonis AL. Comparison of NiTi coil springs vs. elastics in canine retraction. J Clin Orthod 1994;28:293-5. |
10. | Hasan K, Hassan GS, Rahman S, Ali S, Rahman A, Hasan M, Tani RR. Space closure rate in mandibular canine retraction by Ni-Ti closed coil spring: A clinical trial. Med Today 2021;33:90-3. |
11. | Mehta KR, Sable RB. Comparison of the amount of maxillary canine retraction with T-loops using TMA and stainless steel wires. A Clinical study. J Indian Orthod Soc 2013;47:178-83. [Full text] |
12. | Pavlin D, Anthony R, Raj V, Gakunga PT. Cyclic loading (vibration) accelerates tooth movement in orthodontic patients: A double-blind, randomized controlled trial. Semin Orthod 2015;21:187-94. |
13. | Khalid Z, Bangash AA, Anwar A, Pasha H, Amin E. Canine retraction using a closed nickel titanium coil spring and an elastic module. J Coll Physician Surg Pak 2018;28:695-8. |
14. | Mezari A, Ahmed FS. Study of the velocity of upper canine retraction after alveolar corticotomy. J Dentofacial Anom Orthod 2018;21:507. |
15. | Sivarajan S, Doss JG, Papageorgiou SN, Cobourne MT, Weye MC. Mini-implant supported canine retraction with micro-osteoperforation: A split-mouth randomized clinical trial. Angle Orthod 2019;89:183-9. |
16. | Qamruddin I, Khan AG, Asif FM, Karim M, Nowrin SA, Shahid F, Alam MK. Pain perception and rate of canine retraction through self-ligating brackets and conventional elastomeric ligation system: A split mouth study. Pesqui Bras Odontopediatria Clín Integr 2020;20:e5147. |
17. | Shankar S, Chandra S, Shahi A K. A Comparison between space closure by canine retraction with active tiebacks and closed coil springs: A clinical study with the MBT System. Int J Med Res Prof 2017;3:365-70. |
18. | Tawfik M, Elbedwehi A, Abouelnour A. Maxillary canine retraction rate using two different orthodontic mechanics (A prospective clinical study). Al-Azhar J Dent Sci 2021;24:93-100. |
19. | Lotzof LP, Fine HA, Cisneros GJ. Canine retraction: A comparison of two preadjusted brackets systems. Am J Orthod Dentofacial Orthop 1996;110:191-6. |
20. | Limpanichkul W, Godfrey K, Srisuk N, Rattanayatikul C. Effects of low-level laser therapy on the rate of orthodontic tooth movement. Orthod Craniofac Res 2006;9:38-43. |
21. | Dixon V, Read MJF, O'Brien KD, Worthington HV, Mandall NA. A randomized clinical trial to compare three methods of orthodontic space closure. J Orthod 2002;29:31-6. |
22. | Nightingale C, Jones SP. A clinical investigation of force delivery systems for orthodontic space closure. J Orthod 2003;30:229-36. |
23. | Sukurica Y, Karaman A, Gürel HG, Dolanmaz D. Rapid canine distalization through segmental alveolar distraction osteogenesis. Angle Orthod 2007;77:226-36. |
24. | Ravi K, Balasubramaniam MR, George M, Duraisamy S. Comparison of canine retraction using friction less ligature modules with conventional modules- An in vivo study. SRM Univ J Dent Sci 2010;1:150-5. |
25. | Mezomo M, de Lima ES, de Menezes LM, Weissheimer A, Allgayer S. Maxillary canine retraction with self-ligating and conventional brackets- A randomized clinical trial. Angle Orthod 2011;81:292-7. |
26. | Aboul-Ela SM, El-Beialy AR, El-Sayed KM, Selim EM, El-Mangoury NH, Mostafa YA. Miniscrew implant-supported maxillary canine retraction with and without corticotomy-facilitated orthodontics. Am J Orthod Dentofacial Orthop 2011;139:252-9. |
27. | Kalra A, Jaggi N, Bansal M, Goel S, Medsinge SV, Abraham R, Jasoria G. Comparison of rate of canine retraction into recent extraction site with and without gingival fiberotomy: A clinical study. J Contemp Dent Pract 2013;14:419-26. |
28. | Hassan SE, Hajeer MY, Alali OH, Kaddah AS. The effect of using self-ligating brackets on maxillary canine retraction: A split-mouth design randomized controlled trial. J Contemp Dent Pract 2016;17:496-503. |
29. | Alfawal AMH, Hajeer MY, Ajaj MA, Hamadah O, Brad B. Evaluation of piezocision and laser-assisted flapless corticotomy in the acceleration of canine retraction: A randomized controlled trial. Head Face Med 2018;14:4. |
30. | Bhat ZI, Naik CR, Rahalkar JS. Comparison of canine retraction using single and Siamese edgewise brackets: An in vivo study. APOS Trends Orthod 2013;3:91-8. [Full text] |
31. | Abdul Wahab RM, Yamamoto Z, Sintian A, Abu Kasim N, ZainolAbidin IZ, Senafi S, et al. The effects of orthodontic forces during canine retraction using self-ligating brackets on gingival crevicular fluid enzyme activity, canine movement and root resorption. Sains Malaysiana 2015;44:249-56. |
32. | Alqadasi B, Aldhorae K, Halboub E, Mahgoub N, Alnasri A, Assiry A, et al. The effectiveness of micro-osteoperforations during canine retraction: A three-dimensional randomized clinical trial. J Int Soc Prevent Communit Dent 2019;9:637-45.  [ PUBMED] [Full text] |
33. | Thiruvenkatachari B, Ammayappan P, Kandaswamy R. Comparison of rate of canine retraction with conventional molar anchorage and titanium implant anchorage. Am J Orthod Dentofacial Orthop 2008;134:30-5. |
34. | Martins RP, Buschang PH, Gandini LG Jr, Rossouw PE. Changes over time in canine retraction: An implant study. Am J Orthod Dentofacial Orthop 2009;136:87-93. |
35. | Oz AA, Arici N, Arici S. The clinical and laboratory effects of bracket type during canine distalization with sliding mechanics. Angle Orthod 2012;82:326-32. |
36. | Monini ADC, Júnior LGG, Vianna AP, Martins RP. A comparison of lower canine retraction and loss of anchorage between conventional and self-ligating brackets: A single-center randomized split-mouth controlled trial. Clin Oral Investig 2017;21:1047-53. |
37. | Monini ADC, Gandini LG Jr, Vianna AP, Martins RP, Jacob HB. Tooth movement rate and anchorage lost during canine retraction: A maxillary and mandibular comparison. Angle Orthod 2019;89:559-65. |
38. | Abu-Shahba R, Alassiry A. Comparative evaluation of the maxillary canine retraction rate and anchorage loss between two types of self-ligating brackets using sliding mechanics. J Orthod Sci 2019;8:3. |
39. | El-Timamy A, El Sharaby F, Eid F, El Dakroury A, Mostafa Y, Shaker O. Effect of platelet-rich plasma on the rate of orthodontic tooth movement: A split-mouth randomized trial. Angle Orthod 2020;90:354-61. |
40. | Ali TM, Chawshli OF. The effect of submucosal injection of plasma rich platelets on the rate of orthodontically induced canine retraction in subject with bimaxillary protrusion. Sulaimani Dent J 2020;7:70-80. |
41. | Barsoum HA, ElSayed HS, ElSharaby FA, Palomo JM, MostafaYA. Comprehensive comparison of canine retraction using NiTi closed coil springs vs. elastomeric chains: A split-mouth randomized controlled trial. Angle Orthod 2021;91:441-8. |
42. | Akın S, Camcı H. Three-dimensional assessment of two different canine retraction techniques: A randomized split-mouth clinical trial. Prog Orthod 2021;22:24. |
43. | El Gazzar RI, Hafez AM, Shamaa MS, Zaghloul MH, Abdelnaby YL. The effect of submucosal injection of platelet-rich plasma on maxillary canine retraction: Split-mouth randomized controlled trial. Annal Dent Spec 2021;9:67-72. |
44. | Albelasy NF, Abdelnaby YL. Impact of retraction force magnitudes on mobility of maxillary canines: A split-mouth design. Prog Orthod 2022;23:14. |
45. | Türedi M, Yazıcıoğlu S. The effects of increased maxillary canine bracket angulation on tooth movement and alignment efficiency: A prospective clinical study. Turk J Orthod 2022;35:33-8. |
46. | Angel SL, Samrit VD, Kharbanda OP, Duggal R, Kumar V, Chauhan SS, et al. Effects of submucosally administered platelet-rich plasma on the rate of tooth movement: A single-center, split-mouth, randomized controlled trial with clinical and biochemical analysis. Angle Orthod 2022;92:73-9 |
47. | Agha NF, Al-Saleem NR. Different methods to measure canine rotation. Al-Rafidain Dent J 2006;6:122-9. |
48. | Anzer N, Feldmann I, Liv P, Bondemark L. A novel method for superimposition and measurements on maxillary digital 3D models-studies on validity and reliability. Eur J Orthod 2018;40:45-51. |
49. | Choi JI, Cha BK, Jost-Brinkmann PG, Choi DS, Jang IS. Validity of palatal superimposition of 3-dimensional digital models in cases treated with rapid maxillary expansion and maxillary protraction headgear. Korean J Orthod 2012;42:235-41. |
50. | Cevidanes LH, Heymann G, Cornelis MA, DeClerck HJ, Tulloch JF. Superimposition of 3-dimensional cone-beam computed tomography models of growing patients. Am J Orthod Dentofacial Orthop 2009;136:94-9. |
51. | Almeida MA, Phillips C, Kula K, Tulloch C. Stability ofthe palatal rugae as landmarks for analysis of dental casts. Angle Orthod 1995;65:43-8. |
52. | Bailey L, Esmailnejad A, Almeida M. Stability of the palatal rugae as landmarks for analysis of dental casts in extraction and nonextraction cases. Angle Orthod 1996;66:73-8. |
53. | Damstra J, Mistry D, Cruz C, Ren Y. Antero-posterior and transverse changes in the position of the palatal rugae after rapid palatal expansion. Eur J Orthod 2009;31:327-32. |
54. | Christou P, Kiliardis S. Vertical growth-related changes in the positions of the palatal rugae and maxillary incisors. Am J Orthod Dentofacial Orthop 2008;133:81-6. |
55. | Thiruvenkatachari B, Al-Abdallah M, Akram NC, Sandler J, O'Brien K. Measuring-dimensional tooth movement with a 3-dimensional surface laser scanner. Am J Orthod Dentofacial Orthop 2009;135:480-5. |
56. | Cha B, Lee J, Jost-Brinkmann P, Yoshida N. Analysis of tooth movement in extraction cases using three-dimensional reverse engineering technology. Eur J Orthod 2007;29:325-331. |
57. | Van der Linden FP. Changes in the position of the posterior teeth in relation to the ruga points. Am J Orthod 1978;74:142-61. |
58. | Jang I, Tanaka M, Koga Y, Iijima S, Yozgatian JH, Cha BK, et al. A novel method for the Assessment of three-dimensional tooth movement during orthodontic treatment. Angle Orthod 2009;79:447-53. |
59. | Garib D, Miranda F, Yatabe MS, Lauris JRP, Massaro C, McNamara Jr JA, et al. Superimposition of maxillary digital models using the palatal rugae: Does aging affect the reliability? Orthod Craniofac Res 2019;22:183-93. |
[Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]
|