Users Online: 375
Home
About us
Editorial board
Search
Browse articles
Submit article
Instructions
Subscribe
Contacts
Login
» Articles published in the past year
To view other articles click corresponding year from the navigation links on the left side.
All
|
Case Report
|
Case Reports
|
Editorial
|
Guest Editorial
|
Original Articles
|
Review Article
|
Short Communication
|
Systematic Review
Export selected to
Endnote
Reference Manager
Procite
Medlars Format
RefWorks Format
BibTex Format
Show all abstracts
Show selected abstracts
Export selected to
Add to my list
Original Article:
An
in vitro
assessment of the mechanical characteristics of nickel-titanium orthodontic wires in Fluoride solutions with different acidities
Shiva Alavi, Sara Barooti, Ali Borzabadi-Farahani
J Orthodont Sci
2015, 4:52 (29 April 2015)
DOI
:10.4103/2278-0203.156030
PMID
:26020039
Objectives:
The aim was to evaluate the
in vitro
effects of fluoride solutions with different acidities on load-deflection characteristics of nickel-titanium (NiTi) orthodontic wires.
Materials
and
Methods:
In this study, which lasted 30 days, 36 (3 cm long, 0.016 × 0.022 inches, SENT 1622, G & H wire Company, Greenwood, Indiana, USA) NiTi wires, were divided into three experimental groups of 12 each. Two groups were subjected to 0.05 topical fluoride mouthwash with different acidities (G1, pH 4; G2, pH 6.6) for 90 s, twice a day, and kept in normal saline after that. The third group (G3, the control group) was kept in normal saline only. Load and unload forces were measured with three bracket bending test in a universal testing machine (Testometric Co, Rochdale, UK). Loading and unloading plateaus and hysteresis were also recorded. Data were then analyzed using analysis of variance and honestly significant difference Tukey at
P
< 0.05.
Results:
During the loading phase, there was a significant difference between deflections (
P
< 0.001); but there was no interaction effect (
P
= 0.191) and no significant difference among three groups (
P
= 0.268). In the unloading phase, there was a significant difference between deflections (
P
< 0.001) and an interaction effect was also observed (
P
= 0.008). Further, significant differences noted among three groups (
P
= 0.037). Only in the unloading phase, at deflections of 2.2 through 0.2 mm, significant differences between the mean force values of the G1 and G3 groups were observed (
P
= 0.037).
Conclusion:
Based on this
in-vitro
study, compared to neutral fluoride solution, daily mouthwash with a fluoride solution with more acidic pH of 4 affected the NiTi wires load-deflection characteristics during the unloading phase. This finding may have clinical implications and can be further validated by
in-vivo
studies.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (5) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Original Article:
Orthodontic treatment need among special health care needs school children in Dharwad, India: A comparative study
Prajna P Nayak, KVV Prasad, Y Manohar Bhat
J Orthodont Sci
2015, 4:47 (29 April 2015)
DOI
:10.4103/2278-0203.156029
PMID
:26020038
Objectives:
The aim was to assess and compare the prevalence of orthodontic treatment need among various special health care needs (SHCN) schoolchildren and adolescents in Dharwad, India.
Materials and Methods:
This cross-sectional study was carried out among 492 subjects in age group of 12-19 years (mean age 14.02 ± 1.84 standard deviation [SD]) who were examined for occlusal anomalies using dental aesthetic index (DAI). They were classified into five groups as: Visual impairment, speech and hearing disability (SH), physical disability, mentally subnormal and multiple disabilities (MD). Chi-square test was used to compare the orthodontic treatment need among various SHCN groups. One-way ANOVA and ANCOVA were performed to test any significant differences in mean DAI scores among the SHCN groups.
Results:
None of the children were undergoing or had undergone orthodontic treatment for malocclusion. Mean DAI score was 28.81 ± 11.64 (SD). Orthodontic treatment was indicated in 50.2% of study population who had DAI scores of 26 and above. Mandatory orthodontic treatment (DAI >=36) was required in as high as 29% of MD individuals when compared to only 10% of SH individuals. Significant differences in DAI scores were found between the SHCN groups.
Conclusions:
The need for orthodontic treatment among SHCN individuals was found to be high. Yet, absence of any orthodontic treatment for any child points out to the fact that the dental services are highly needed in these individuals.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (3) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Original Article:
In vitro
evaluation of frictional forces of two ceramic orthodontic brackets versus a stainless steel bracket in combination with two types of archwires
Valiollah Arash, Mahmoud Rabiee, Vahid Rakhshan, Sara Khorasani, Farhad Sobouti
J Orthodont Sci
2015, 4:42 (29 April 2015)
DOI
:10.4103/2278-0203.156028
PMID
:26020037
Purpose:
The aim of this study was to compare frictional forces between monocrystalline alumina (MA), polycrystalline alumina (PA), and stainless steel (SS) brackets with two SS wires: Rectangular and round.
Materials
and
Methods:
In this
in vitro
study, 60 0.022" brackets [20 PA (0° torque, Forestadent, Germany) and 20 MA (0° torque, Ormco, California, USA)] brackets plus 20 SS brackets (0° torque, Foretadent, Germany) and 60 SS archwires (30 rectangular 0.019" ×0.025" archwires and 30 round 0.018" archwires, Ortho Technology, USA) were used in subgroups of 10 from the combination of all brackets and all archwires. A universal testing machine (Instron, Model STM 250, Germany) was used to investigate the static frictional resistance. The angulation between the bracket and wire was 0°, and the wires were pulled through the slots at a crosshead speed of 10 mm/min. Two-way and one-way analyses of variance (ANOVA) and Tukey tests were used to analyze the data.
Results:
Mean (SD) static frictional force for each group was as follows: MA + round: 3.47 (0.38); MA + rectangular: 4.05 (0.47); PA + round: 4.14 (0.37); PA + rectangular: 4.45 (0.65); SS + round: 3.28 (0.22); and SS + rectangular: 4.22 (0.61). Significant effects of bracket types (
P
= 0.001) and archwire types (
P
= 0.000) on the friction force were detected using ANOVA. Tukey test indicated significant differences between PA brackets with both SS and MA brackets (
P
< 0.05), but not between SS and MA brackets. The two archwires as well had significantly different effects (Tukey
P
= 0.000).
Conclusions:
Based on the present in-vitro study, the PA brackets might create higher frictional forces compared to both SS and MA brackets. The rectangular 0.019" ×0.025" archwire might create greater forces than round 0.018" archwire.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (10) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Original Article:
Effect of multiple debonding sequences on shear bond strength of new stainless steel brackets
Ladan Eslamian, Ali Borzabadi-Farahani, Pegah Tavakol, Ali Tavakol, Nazila Amini, Edward Lynch
J Orthodont Sci
2015, 4:37 (29 April 2015)
DOI
:10.4103/2278-0203.156027
PMID
:26020036
Objectives:
This in-vitro study aimed at evaluating the effect of three debonding sequences on the shear bond strength (SBS) of new stainless steel (SS) brackets.
Materials and Methods:
Stainless steel twin brackets (0.022-inch, American Orthodontics, Sheboygan, WI, USA) were bonded with light cure adhesive (Transbond XT, 3M Unitek, St. Paul, MN, USA) to 80 newly extracted human premolars after acid etching with 37% phosphoric acid (30 s). Brackets were debonded with a universal testing machine, and new brackets were bonded to teeth using the same adhesive and same manner. This process was repeated twice, and brackets were debonded within 24 h after bonding. The longitudinal changes of average SBS were assessed with the repeated measures ANOVA.
Post-hoc
tests using the Bonferroni correction were also used to compare the average SBS at three debonding sequences.
Result:
The mean SBS decreased significantly after each debonding sequence (
P
< 0.01). The corresponding mean values (standard deviation, 95% CI) after the first, second, and third debonding sequences were 22.88 MPa (4.08, 21.97-22.79), 19.36 MPa (4.54, 18.62-20.64), and 16.67 MPa (4.27, 15.72-17.62), respectively. There was no significant difference among the adhesive remnant index (ARI) scores of three debonding sequences (χ
2
= 5.067, df = 6,
P
= 0.53).
Conclusion:
Average SBS after three debonding sequences was significantly decreased, but was above the recommended 5.9-7.8 MPa.
In-vivo
studies are required to validate the finding of this study.
[ABSTRACT]
[HTML Full text]
[PDF]
[Mobile Full text]
[EPub]
[Citations (9) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Feedback
Subscribe
Advanced Search
Month wise articles
Figures next to the month indicate the number of articles in that month
2023
April
[
11
]
March
[
24
]
2022
October
[
11
]
August
[
15
]
May
[
24
]
January
[
6
]
2021
October
[
7
]
August
[
6
]
July
[
5
]
February
[
6
]
2020
November
[
5
]
August
[
5
]
July
[
4
]
February
[
5
]
2019
October
[
4
]
August
[
5
]
May
[
5
]
February
[
5
]
2018
November
[
5
]
September
[
5
]
June
[
6
]
February
[
8
]
2017
October
[
7
]
June
[
6
]
May
[
6
]
January
[
5
]
2016
October
[
5
]
July
[
5
]
March
[
6
]
February
[
7
]
January
[
6
]
2015
July
[
7
]
April
[
4
]
January
[
6
]
2014
October
[
7
]
July
[
5
]
May
[
5
]
February
[
4
]
2013
December
[
5
]
October
[
5
]
July
[
5
]
April
[
5
]
January
[
4
]
2012
November
[
5
]
August
[
5
]
April
[
5
]
Sitemap
|
What's New
Feedback
|
Copyright and Disclaimer
|
Privacy Notice
© Journal of Orthodontic Science | Published by Wolters Kluwer -
Medknow
Online since 01 August, 2011